Same board. A closer look at the traces.
First robot version.
Now.
The accepted robot-routed snapshot beside the current board, after manual edits and two trace-cleanup passes. Select a net to follow the same connection in both.
Click copper to select a net. Zoom, then drag to pan; both views stay aligned.
01 / First robot version
02 / Now
Loading copper…
Both views use the same board coordinates and scale. Inner layers remain in the front view. GND is green; VCC is orange. The previews include saved copper fills.
What changed, and what was checked?
From the saved robot route to today
The two cleanup passes retained 68 simplified connections and then 50 freshly routed connections. The fresh pass searched with pours excluded, then refilled and checked the zones. It removed 97 bends, adding 5.69 mm across the 50 affected paths.
This is a comparison of saved states. It includes the manual work between them.
CAD checks
The first snapshot had zero native DRC, open-connection and schematic-parity findings. The current snapshot has no opens or parity findings and retains one existing dangling-track warning on /ADDR0. All 76 nets pass the independent connectivity check.
First robot DRC ↗ · Current DRC ↗
CAD previews do not establish physical or EMC performance.